Lock and fitting dimensions
| Specifications | Dimensions from model documentation |
|---|---|
| Backset E | 60 mm |
| Centre distance | 85 mm |
| Faceplate dimensions | 2300×24×3 mm |
| Main deadbolt throw | 20 mm |
| Handle spindle | 8 mm |
Check the backset, centre distance, faceplate and mounting points against the specific model drawing.
Browse related directorySpecifications
- Construction
- Performa Mechanical multipoint sliding-deadbolt lock
- Backset E
- 60 mm
- Centre distance
- 85 mm
- Faceplate dimensions
- 2300×24×3 mm
- Faceplate profile
- Flat
- Faceplate material
- Stainless steel
- Locking configuration
- Sliding deadbolts in the main and auxiliary locks
- Main deadbolt throw
- 20 mm
- Cylinder interface
- Euro-profile cylinder
- Handle spindle
- 8 mm
- Latch
- Reversible; can be replaced with 040940 roller or 040950 blanking piece
Backset, centre distance and faceplate
This model's horizontal backset is 60 mm, and the vertical handle-to-cylinder operating centre distance is 85 mm. Check the two dimensions separately. Door thickness cannot replace backset, and versions with 85 mm and 92 mm centre distances cannot be interchanged directly.
2300 mm is the long faceplate length, not a guarantee of compatible door height. The flat faceplate has a width of 24 mm and thickness of 3 mm; check the door-edge mortice.
Locking construction and operation
The main lock and both ends use sliding deadbolts. Confirm the depth and position of all three keeps; do not copy the hook-bolt version's keep arrangement without checking.
The mechanical version's latch can be replaced with a roller or blanking piece. The matching electric strike is a separately ordered accessory and does not mean the main lock itself already has electric drive.
The catalogue provides a cam stop device for when no cylinder is installed; assemble and test according to the manufacturer's instructions.
Limitations
- Check the positions of the main lock and upper/lower auxiliary locks against the complete catalogue drawing and frame keeps; faceplate length alone does not establish compatibility.
- This page does not infer fire, escape or local security grades; check installation documents for the electric version's supply and access-control connections.
Sources
ISEO Catalogue 02 .42, pages 2-108, 2-109Manufacturer documents are provided in their original language.