Specifications
- Operating mode
- Releases only during powered pulse
- Catalogue voltage
- 24 V AC/DC
- Catalogue current
- 0.5 A
- Conflicting electrical data
- 15 W on the same page conflicts with listed voltage and current. Rated power is not established; verify against the nameplate and manufacturer instructions
- Drawing dimensions
- 133×37×46.5 mm
- Application restrictions
- Not suitable for fire doors
Model application and configuration
Releases only during powered pulse determines the relationship between the electrical signal and lock release. The catalogue records voltage 24 V AC/DC, but 15 W on the same page conflicts with voltage and current, so complete rated electrical specifications cannot be established. The three versions have different operating modes. Check the nameplate and manufacturer wiring instructions before deciding on replacement.
Checks before ordering and replacement
Use complete order code 5680020 to confirm the version's nameplate, rated input and output, wiring diagram, load current and protection requirements with the manufacturer. The catalogue has the electrical-data conflicts described above and should not be used directly to select a supply or install wiring. After confirmation, check the matching device's operating mode and required supply conditions.
Limitations
- The catalogue's 15 W does not agree with voltage and current figures in the same location. This page does not assert a definite power rating; check the manufacturer's electrical documentation.
- Historical catalogue configuration. Fire and escape applications require checking the specific door set and component combination. This page does not certify current compliance of the complete door.
- Optional accessories are not standard equipment. Diagrams are not construction, drilling or wiring drawings.
Sources
ISEO Catalogue 05 .42, PDF page 83Manufacturer documents are provided in their original language.