Locks, components and selection

Search

CISA 1C161103097 Professional Plus 2 C1611 door closer

Professional Plus 2 C1611 door closer; Series: Professional Plus 2 C1611; Mounting/opening direction: follow the corresponding installation template; Arm configuration: link arm with hold-open; Catalogue power size: 2–4; Catalogue door width: 850–1100 mm.

CISA 1C161103097 — Official series illustration, not a photo of this exact size variant; consult model specifications.
Official series illustration, not a photo of this exact size variant; consult model specifications.Image source
CISA 1C161103097 door-width parameter 850–1100 mm explanation
Original site parameter-range explanation; use together with installation conditions; it does not show the product outline, hole spacing or installation method.

Door closer mounting dimensions

Dimensions from model documentation
SpecificationsDimensions from model documentation
Catalogue door width850–1100 mm

Check the mounting layout, arm type, door mass and width in the model documentation.

Browse related directory

Specifications

Series
Professional Plus 2 C1611
Mounting/opening direction
Follow the corresponding installation template
Arm configuration
Link arm with hold-open
Catalogue power size
2–4
Catalogue door width
850–1100 mm
Catalogue door weight
40–80 kg
Adjustments
Power adjusted by body screw; Closing, final latching and backcheck

Configuration differences and selection conditions

This order row for Professional Plus 2 C1611 specifies a link arm with hold-open; the manufacturer lists power size 2–4. Door width 850–1100 mm and weight 40–80 kg must be checked with the specific mounting position and power conditions; arbitrary width/weight combinations are not permitted.

Hold-open, backcheck and delayed closing are distinct functions. The hold-open configuration is for conditions requiring the door to remain open; Suitability for a particular fire or evacuation door requires the specific documents for this configuration and door assembly.

The Professional Plus series catalogue explicitly states that hold-open is not suitable for fire doors; Fire symbols on other configurations on the same page do not remove this restriction.

Limitations

  • The information follows the specific ordering row in the catalogue; the series standards description does not establish certification of the current complete door or every hold-open configuration.
  • This original parameter illustration does not represent the actual outline, hole positions or an installation template.

Sources

CISA English catalogue, PDF page 588 / printed page 584

Manufacturer documents are provided in their original language.

Related articles

ZamokWiki · A source-backed reference library for locks

Manufacturer documents are provided in their original language.